GLR (fuse) HLR (fuse holder) Non-rejecting, fast-acting fuse and in-line fuse holders
Catalog symbol: GLR (fuse) HLR (fuse holder)
Ampere Rating: 3/16 - 15 A
Voltage Rating: 300 Volts AC or less
Interrupting Rating: 10,000 A
Agency information Fuse
• UL® Listed, Std. 248-14, 3/16-15A/300Vac, Guide JDYX, File E19180
• CSA® Certified, C22.2 No. 248.14, 0-10A/300Vac, Class 1422-01, File 53787
Fuse holder HLR
• UL Recognized, 12A, 300Vac, Guide IZLT2, File E14853
• CSA Certified, 12A, 300Vac, Class 6225-01, File 47235
HLR-2A and HRL-2L
• UL Recognized, 15A, 300Vac, Guide IZLT2, File E14853
• CSA Certified, 15A, 300Vac, Class 6225-01, File 47235 A
• CSA Certified, 10A, 300Vac, Class 6225-01, File 47235
Catalog Numbers (Amps)
Catalog Numbers
Catalog Numbers
Catalog Numbers
Catalog Numbers
GLR-3/16
GLR-1-6/10
GLR-5
GLR-9
GLR-1/2
GLR-2
GLR-6
GLR-10
GLR-1
GLR-3
GLR-7
GLR-12
GLR-1-1/2
GLR-4
GLR-8
GLR-15*
* Must be used with the HLR-2A holder rated to 15A.
Product features
• GLR fuse and knob are an integral one-piece unit. There are no replacement knobs (caps) • Units can be panel mounted with a separate steel clip. For knockout hole mounting (see dimensions), order catalog number BK/A-104. For the keyhole punch type hole mounting, order catalog number 6374 for panels 0.043” to 0.062” thick, or catalog number 4909 for panels 0.030” to 0.042” thick.
• The HLR holder comes with 6 inches of red #18 insulated solid copper wire attached to the lineside terminal, customer inserts a #18 insulated solid copper wire into loadside terminal
• Order holder catalog number HLR-2A to obtain 6 inches of black #18 insulated solid copper wire pre-installed in the loadside terminal
• Order catalog number HLR-2L to obtain 6 inches of black #18 insulated solid copper wire packaged loose (uninstalled)
• An alternative to the HLR fuse holder is the “A” fuse holder. The “A” fuse holder comes WITHOUT leads. The customer inserts #18 insulated solid copper wire into the lineside and the loadside terminals. The “A” fuse holder has the same body dimensions, utilizes the same mounting hole, and takes the same mounting clips as the HLR, HLR-2A and HLR-2L
• Do not put tension on the fuse holder’s lineside terminal
HLR fuse holder catalog numbers
Catalog No.
Description
HLR
Holder with installed linseide terminal wire for 3/16 to 12 amp GLR fuses
HLR-2A
Holder with installed lineside and loadside terminal wires for 3/16 to 15 amp GLR fuses
HLR-2L
Holder with uninstalled lineside and loadside terminal wires for 3/16 to 15 amp GLR fuses
A