Product Information

Eaton's Bussmann Division fuses and surge circuit protection ...

HOME    美标圆柱形熔断器    FWP 690V 14x51mm Class aR 高速熔断器    FWP系列,圆柱形快速熔断器14 x 51mm

The protection you rely on.

             The Bussmann brand continues to reflect a long-standing tradition of providing fusible circuit protection and electrical safety solutions that protect equipment and enable reliable, efficient power distribution.

             When you bring together the industry’s top innovator in fuse technology with unmatched expertise in circuit breakers you get leadership in circuit protection. Eaton’s heritage in circuit breaker development coupled with the number one Bussmann brand in fuses,means the choice is no longer fuse or breaker. Its fuse and breaker.

  • BM & CRO 

    Best Solution For Your Business.

     FWP 14x51 mm Class aR fuses


     

     

    Specifications:Eaton’s Bussmann series FWP 14x51 mm class aR fuses provide short-circuit protection and are used to protect AC/DC drives and semi conductors

    They are available with an optional striker to provide local indication of fuse status or work in the CH14 modular fuse holder to provide remote fuse indication capabililty.

     

    Description: Ferrule style high speed fuses with and without indicating striker. Dimensions: See dimensions illustrations.

     

    Ratings:

    Volts: 690Vac (IEC) — 700Vac (UL) — 800Vdc (5-50A)

    Amps: 1-50A

    IR: 200kA RMS Sym. — 50kA @800Vdc

     

    Agency Information: CE, UL Recognition, CSA

    Component Acceptance for versions without indicator only.

     

    Electrical Characteristics

    Total Clearing I2t

    The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms)

     

    Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%.

     

    Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current.

     

    Without Striker Catalog Numbers (Amps)

    Catalog Numbers

    Catalog Numbers

    Catalog Numbers

    Catalog Numbers

    FWP-1A14Fa

    FWP-5A14Fa

    FWP-20A14Fa

    FWP-40A14Fa

    FWP-2A14Fa

    FWP-6A14Fa

    FWP-25A14Fa

    FWP-50A14Fa

    FWP-3A14Fa

    FWP-10A14Fa

    FWP-30A14Fa

     

    FWP-4A14Fa

    FWP-15A14Fa

    FWP-32A14Fa

     

     

    With Striker Catalog Numbers (Amps)

     

    Catalog Numbers

    Catalog Numbers

    Catalog Numbers

    Catalog Numbers

    FWP-10A14FI

    FWP-20A14FI

    FWP-30A14FI

    FWP-40A14FI

    FWP-15A14FI

    FWP-25A14FI

    FWP-32A14FI

    FWP-50A14FI

    • Watts loss provided at rated current.

    • See accessories on page 216.

     

    Fuse type

    Fuse symbol

    Rated voltage

    Rated current (amps)

    12t (A2s)

    Watts loss (w)*

    Catalog no

    Pre-arcing

    Clearing at 600 Vac

    without striker

    14*51mm (9/16*2)

    700Vac UL

    1

    0.04

    0.41

    6.7

    FWP-1A14Fa

    2

    0.08

    0.11

    8.7

    FWP-2A14Fa

    3

    0.11

    0.26

    2.8

    FWP-3A14Fa

    4

    0.1

    0.23

    3

    FWP-4A14Fa

    600Vac (IEC)700 Vac/dc (UL)

    5

    2

    11

    1.6

    FWP-5A14Fa

    10

    4

    22

    4

    FWP-10A14Fa

    15

    10

    70

    5.5

    FWP-15A14Fa

    20

    26

    180

    6.6

    FWP-20A14Fa

    25

    49

    320

    7

    FWP-25A14Fa

    30

    58

    400

    9

    FWP-30A14Fa

    32

    68

    600

    8

    FWP-32A14Fa

    40

    84

    750

    8

    FWP-40A14Fa

    50

    200

    1800

    9

    FWP-50A14Fa

    with striker

    14*51mm (9/16*2)

    700 Vac/600 Vdc (UL)

    10

    4

    32

    2

    FWP-10A14FI

    15

    7

    63

    4

    FWP-15A14FI

    20

    26

    234

    4

    FWP-20A14FI

    25

    42

    378

    4

    FWP-25A14FI

    30

    52

    468

    6

    FWP-30A14FI

    32

    68

    600

    8

    FWP-32A14FI

    40

    84

    750

    8

    FWP-40A14FI

    50

    200

    1800

    9

    FWP-50A14FI

     

    Carton Quantity

    Amp Rating

    Carton Qty

    1-60

    10

     

    Features and Benefits

    • Excellent cycling capability and DC performance

    • Low arc voltage and low energy let-through (I2t)

    • Low watts loss in a compact size

    • Used with finger-safe holders/blocks

     

  • Why Choose Us

    ________________________________________________________________________

     

    Are you still finding the suppliers that you can order small quantity with lower price?
    www.cooper-bussmann.cn is the best solution for your business.
    You will know after you see following comparisons.

    ________________________________________________________________________

     

     

    Transportation cost:

    The quantity is greater than MOQ (minimum packing quantity), no charge is charged in China.

    The quantity is less than MOQ (minimum packing quantity), Shun Feng express / Debon logistics, freight collect.

     

    Cash delivery on spot

    More available in 6-8 weeks

    Total Price All the taxes are included

     

    * Questions before or after purchase? Get help at any time!

    * Price not maintained will need to be verified 

    * Total Available: Please call for availability

     

    ________________________________________________________________________

     

     

    Have Any Questions !

    Don’t Hesitate To Contact Us Any Time !

     

    ________________________________________________________________________

Online Solution

验证码